ViSAGE MD 13400 Bedienerhandbuch

Stöbern Sie online oder laden Sie Bedienerhandbuch nach Blutdruck-Geräte ViSAGE MD 13400 herunter. ViSAGE MD 13400 Instruction manual Benutzerhandbuch

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken

Inhaltsverzeichnis

Seite 1 - Daily 8:00 am - 12:00 am CST

premium wrist Model: MD 1010 WBPM10 Series / MD 13400instruction manualblood pressure monitorLIFESTYLEToll Free Customer Support Line(866) 633-4660Dai

Seite 2 - Contents

11What is High Blood Pressure and how is it controlled?High Blood Pressure, also called by its medical term Hypertension, is an abnormally high arteri

Seite 3

12How does the blood pressure monitor work?Your blood pressure monitor contains high quality components for measuring and to display the results on th

Seite 4 - Introduction

13Measuring rangeThe blood pressure monitor shows your blood pressure (SYS. = systolic and DIA. = diastolic value), pulse and the time and date on th

Seite 5 - Safety Information

14Blood pressure classi cation according to WHO in mmHg1 Normal range2 Borderline high3 High blood pressure range13400 EN Aldi US RC6 Content.i

Seite 6 - Safe handling of batteries

15Range SystolicmmHgDiastolicmmHgIndicator Low blood pressureUnder 90 Under 50 GreenNormal blood pressure91–129 51–84 GreenBorderline high blood press

Seite 7 - Service & Repairs

16About your measurement resultsIf the measurements obtained give you cause to be concerned about your health, consult with your physician or licensed

Seite 8 - Proper use

17Before taking your blood pressure measurementNote the following points so that the measurement results give a realistic representation of your blood

Seite 9 - What is blood pressure?

18• Please ensure that you always measure your blood pressure under the same conditions! Also note the information about maintaining the correct post

Seite 10

19Initial operationDevice overview1 User button 2 Clock button3 ON/OFF button4 Battery compartment5 Cu 6 Save button7 WHO color indicat

Seite 11 - How does the blood pressure

20Display1 AVG: Average blood pressure2 Battery indicator3 M: Display of stored measurement results4 Systolic blood pressure5 Diastolic bloo

Seite 12 - Measuring range

3ContentsIntroduction ... 5Safety Information ...

Seite 13

21Inserting batteries  Remove the cover of the battery compartment at the notch in the direction of the arrow.  Insert two 1.5 V R03/LR03/AAA alkali

Seite 14

22Always change both batteries! Never use new and old batteries together or di erent types of batteries.Do not use rechargeable batteries for operati

Seite 15

23  Con rm your selection by pressing the clock button and the display will change to the hour setting.  Press the M button until the current tim

Seite 16

24Putting on the wrist cuff  Remove clothing from left arm or roll up sleeve making sure it is not too tight on your arm.  Attach the wrist cu in

Seite 17

25 Correct position for measurementTo measure your blood pressure, sit comfortably on a chair, take 5 or 6 deep breaths and relax. Place your left elb

Seite 18 - Device overview

26It is important to measure your blood pressure at home and at the same time each day so that the blood pressure, which can change over the course of

Seite 19

27The battery symbol, the blinking cu in ation symbol and the selected user are shown on the display.Do not move the cu , your arm or hand muscles

Seite 20 - Inserting batteries

28Automatic measurementIf the cu pressure is too low, the device stops measuring and in ates the cu again. Measurement starts when the correct cu

Seite 21 - Setting the date & time

29User settingsThe blood pressure monitor has two memory banks, which allow two di erent users to save up to 60 measurements each. The device calcula

Seite 22

30Retrieving stored measurement results  Press the user button to switch on the device.  Press the user button again to select the desired user.

Seite 23 - Putting on the wrist cuff

4Setting the date & time ... 22Putting on the wrist cu ... 24Correct pos

Seite 24

31Deleting memory valuesYou can delete individually saved measurements or all of the measurements for each user.  Press the ON/OFF button to switch

Seite 25

32  Press the user button , CL and 00 will be shown on the display. The value has now been deleted.  In order to delete all of the saved measurement

Seite 26

33  Press the user button , CL and 00 will be shown on the display. All of the saved measurements for the selected user have now been deleted.13400 E

Seite 27 - Arrhythmia detection

34Caring for your blood pressure monitorCleaning/storageOnly use a dry, soft cloth to clean the device. Do not use chemical solutions or cleaning prod

Seite 28 - Selecting user

35Waste disposalPackagingYour device has been packaged to protect it from damage in transit. The packaging is made of environmentally friendly materia

Seite 29

36TroubleshootingIf there are error messages or incorrect measurements displayed, remove the batteries and insert them again after about one minute.Er

Seite 30 - Deleting memory values

37Error Possible causes and solutionsE 3 The cu is not attached correctly.Fit the cu correctly and take a new measurement.E 4 An error has occurre

Seite 31

38Technical dataMeasurement method: OscillometricMeasuring range Blood pressure: 30 ~ 280 mmHgPulse: 40 ~ 180 beats/min.Power supply: 2 x 1.5 V al

Seite 32 - , CL and 00 will be shown

39TemperaturesOperating temperature: +50 ~ +104 °F, at humidity 30–85%Storage temperature: −4 ~ +140 °F, at humidity 10–95% Cu size: 5.3” ~ 7.68”S

Seite 33 - Cleaning/storage

40FCC StatementNOTE:POTENTIAL FOR RADIO/TELEVISION INTERFERENCE (for U.S.A. only)This product has been tested and found to comply with the limits for

Seite 34 - Waste disposal

5IntroductionThank you for purchasing the Welby® Wrist Blood Pressure Monitor. This fully automatic device measures blood pressure and pulse rate and

Seite 35 - Troubleshooting

41circuit different from that to which the receiver is connected.• Consult the dealer or an experienced radio/TV technician for help.You may also  n

Seite 36

42Blood pressure reading logUser 1Date & TimeSys Dia Pulse Wt. Notes13400 EN Aldi US RC6 Content.indd 4013400 EN Aldi US RC6 Content.indd 40 2

Seite 37 - Technical data

43User 2Date & TimeSys Dia Pulse Wt. Notes13400 EN Aldi US RC6 Content.indd 4113400 EN Aldi US RC6 Content.indd 41 20.04.11 09:52:1920.04.11

Seite 38

44Limited WarrantyPLEASE READ THIS LIMITED WARRANTY CAREFULLY TO UNDERSTAND YOUR RIGHTS AND OBLIGATIONS.MEDION warrants that the Welby® Premium Wrist

Seite 39 - FCC Statement

45limited warranty extends to repaired products and replacement products only through the end of the original limited warranty period.In no event shal

Seite 40

46To obtain a RMA please contact MEDION Toll Free Customer Care at:866-633-4660Daily 8:00 am - 12:00 am CSTexcept holidaysEmail Support (Available 24

Seite 41 - Blood pressure reading log

premium wrist Model: MD 1010 WBPM10 Series / MD 13400instruction manualblood pressure monitorLIFESTYLEToll Free Customer Support Line(866) 633-4660Dai

Seite 42 - Sys Dia Pulse Wt. Notes

6Safety InformationGeneral• This device is intended for home use only.• Do not use this device for self-diagnosis or self-treatment. Contact your ph

Seite 43 - Limited Warranty

7Safe handling of batteriesBatteries may contain combustible materials. If not handled correctly, batteries can leak, become very hot, ignite or even

Seite 44

8inserted to avoid short circuits.• Remove discharged batteries from the device immediately.• Remove the batteries from the device if you do not int

Seite 45

9About this deviceThe device is used to measure blood pressure at the wrist and can save 60 measurement values in each of two memory spaces.Proper use

Seite 46

10Frequently Asked QuestionsWhat is blood pressure?Blood pressure is the force exerted by blood against the walls of the aterties as blood is pumped t

Kommentare zu diesen Handbüchern

Keine Kommentare